0.1.3 bandpass

Requires:

Synopsis Calculates a bandpass calibration solution Description

Determines the amplitude and phase as a function of frequency for each spectral window containing more than one channel. Strong sources (or many observations of moderately strong sources) are needed to obtain accurate bandpass functions. The two solution choices are: Individual antenna/based channel solutions ’B’; and a polynomial fit over the channels ’BPOLY’. The ’B’ solutions can determined at any specified time interval, and is recommended in most applications.

Arguments





Inputs

vis

Nome of input visibility file

allowed:

string

Default:

caltable

Name of output gain calibration table

allowed:

string

Default:

field

Select field using field id(s) or field name(s)

allowed:

string

Default:

spw

Select spectral window/channels

allowed:

string

Default:

selectdata

Other data selection parameters

allowed:

bool

Default:

True

timerange

Select data based on time range

allowed:

string

Default:

uvrange

Select data within uvrange (default units meters)

allowed:

any

Default:

variant

antenna

Select data based on antenna/baseline

allowed:

string

Default:

scan

Scan number range

allowed:

string

Default:

msselect

Optional complex data selection (ignore for now)

allowed:

string

Default:

solint

Solution interval

allowed:

any

Default:

variant inf

combine

Data axes which to combine for solve (scan, spw, and/or field)

allowed:

string

Default:

scan

refant

Reference antenna name

allowed:

string

Default:

minblperant

Minimum baselines _per antenna_ required for solve

allowed:

int

Default:

4

solnorm

Normalize average solution amplitudes to 1.0 (G, T only)

allowed:

bool

Default:

False

bandtype

Type of bandpass solution (B or BPOLY)

allowed:

string

Default:

B

append

Append solutions to the (existing) table

allowed:

bool

Default:

False

fillgaps

Fill flagged solution channels by interpolation

allowed:

int

Default:

0

degamp

Polynomial degree for BPOLY amplitude solution

allowed:

int

Default:

3

degphase

Polynomial degree for BPOLY phase solution

allowed:

int

Default:

3

visnorm

Normalize data prior to BPOLY solution

allowed:

bool

Default:

False

maskcenter

Number of channels to avoid in center of each band

allowed:

int

Default:

0

maskedge

Fraction of channels to avoid at each band edge (in %)

allowed:

int

Default:

5

gaintable

Gain calibration table(s) to apply on the fly

allowed:

stringArray

Default:

gainfield

Select a subset of calibrators from gaintable(s)

allowed:

stringArray

Default:

interp

Interpolation mode (in time) to use for each gaintable

allowed:

stringArray

Default:

spwmap

Spectral windows combinations to form for gaintables(s)

allowed:

intArray

Default:

gaincurve

Apply internal VLA antenna gain curve correction

allowed:

bool

Default:

False

opacity

Opacity correction to apply (nepers)

allowed:

double

Default:

0.0

parang

Apply parallactic angle correction

allowed:

bool

Default:

False

Example

 
 
       Determines the amplitude and phase as a function of frequency for  
       each spectral window containing more than one channel.  Strong sources  
       (or many observations of moderately strong sources) are needed to obtain  
       accurate bandpass functions.  The two solution choices are: Individual  
       antenna/based channel solutions ’B’; and a polynomial fit over the channels  
       ’BPOLY’.  The ’B’ solutions can determined at any specified time interval, and  
       is recommended if each channel has good signal-to-noise.  Other, ’BPOLY’ is  
       recommended.  
 
      Keyword arguments:  
      vis -- Name of input visibility file  
              default: none; example: vis=’ngc5921.ms’  
      caltable -- Name of output bandpass calibration table  
              default: none; example: caltable=’ngc5921.bcal’  
 
      --- Data Selection (see help par.selectdata for more detailed information)  
 
      field -- Select field using field id(s) or field name(s).  
                 [run listobs to obtain the list id’s or names]  
              default: ’’=all fields  
              If field string is a non-negative integer, it is assumed a field index  
                otherwise, it is assumed a field name  
              field=’0~2’; field ids 0,1,2  
              field=’0,4,5~7’; field ids 0,4,5,6,7  
              field=’3C286,3C295’; field named 3C286 adn 3C295  
              field = ’3,4C*’; field id 3, all names starting with 4C  
      spw -- Select spectral window/channels  
              default: ’’=all spectral windows and channels  
              spw=’0~2,4’; spectral windows 0,1,2,4 (all channels)  
              spw=’<2’;  spectral windows less than 2 (i.e. 0,1)  
              spw=’0:5~61’; spw 0, channels 5 to 61  
              spw=’0,10,3:3~45’; spw 0,10 all channels, spw 3, channels 3 to 45.  
              spw=’0~2:2:6’; spw 0,1,2 with channels 2 through 6 in each.  
              spw=’0:0~10;15~60’; spectral window 0 with channels 0-10,15-60  
                        NOTE: ’;’ to separate channel selections  
              spw=’0:0~10,1:20~30,2:1;2;3’; spw 0, channels 0-10,  
                       spw 1, channels 20-30, and spw 2, channels, 1,2 and 3  
      selectdata -- Other data selection parameters  
              default: True  
      timerange  -- Select data based on time range:  
              default = ’’ (all); examples,  
              timerange = ’YYYY/MM/DD/hh:mm:ss~YYYY/MM/DD/hh:mm:ss’  
              Note: if YYYY/MM/DD is missing dat defaults to first day in data set  
              timerange=’09:14:0~09:54:0’ picks 40 min on first day  
              timerange= ’25:00:00~27:30:00’ picks 1 hr to 3 hr 30min on next day  
              timerange=’09:44:00’ data within one integration of time  
              timerange=’>10:24:00’ data after this time  
      uvrange -- Select data within uvrange (default meters)  
              default: ’’ (all); example:  
              uvrange=’0~1000kl’; uvrange from 0-1000 kilo-lamgda  
              uvrange=’>4kl’;uvranges greater than 4 kilo-lambda  
      antenna -- Select data based on antenna/baseline  
              default: ’’ (all)  
              If antenna string is a non-negative integer, it is assumed an antenna index  
                otherwise, it is assumed as an antenna name  
              antenna=’5&6’; baseline between antenna index 5 and index 6.  
              antenna=’VA05&VA06’; baseline between VLA antenna 5 and 6.  
              antenna=’5&6;7&8’; baseline 5-6 and 7-8  
              antenna=’5’; all baselines with antenna 5  
              antenna=’5,6,10’; all baselines with antennas 5, 6 and 10  
       scan -- Select data based on scan number - New, under developement  
               default: ’’ (all); example: scan=’>3’  
       msselect -- Optional complex data selection (ignore for now)  
 
       --- Solution parameters  
       solint --  Solution interval (units optional)  
              default: ’inf’ (~infinite, up to boundaries controlled by combine);  
              Options: ’inf’ (~infinite), ’int’ (per integration), any float  
                       or integer value with or without units  
              examples: solint=’1m’; solint=’60s’, solint=60 --> 1 minute  
                        solint=’0s’; solint=0; solint=’int’ --> per integration  
                        solint-’-1s’; solint=’inf’ --> ~infinite, up to boundaries  
                        enforced by combine  
       combine -- Data axes to combine for solving  
              default: ’scan’ --> solutions will break at field and spw boundaries,  
                        but may extend over multiple scans (per field and spw) up  
                        to solint.  
              Options: ’’,’scan’,’spw’,field’, or any comma-separated combination  
              example: combine=’scan,spw’  --> extend solutions over scan boundaries  
                       (up to the solint), and combine spws for solving  
       refant -- Reference antenna name (string)  
               default: ’’ (no reference antenna)  
                example: refant=’13’ (antenna with index 13)  
                       refant=’VA04’ (VLA antenna #4)  
               Use ’go listobs’ for antenna listing  
       minblperant -- Minimum number of baselines required per antenna for each solve  
                    Antennas with fewer baaselines are excluded from solutions. Amplitude  
                    solutions with fewer than 4 baselines, and phase solutions with fewer  
                    than 3 baselines are only trivially constrained, and are no better  
                    than baseline-based solutions.  
                    default: 4  
                    example: minblperant=10  => Antennas participating on 10 or more  
                             baselines are included in the solve  
       solnorm -- Normalize bandpass amplitudes and phase for each  
               spw, pol, ant, and timestamp  
               default: False (no normalization)  
       bandtype -- Type of bandpass solution (B or BPOLY)  
               default: ’B’; example: bandtype=’BPOLY’  
               ’B’ does a channel by channel solution for each  
                   specified spw.  
               ’BPOLY’ is somewhat experimental. It will fit an  
                   nth order polynomial for the amplitude and phase  
                   as a function of frequency. Only one fit is made  
                   for all specified spw, and edge channels should be  
                   omitted.  
                Use taskname=plotcal in order to compare the results from  
                   B and BPOLY.  
       fillgaps -- Fill flagged solution channels by interpolation  
               default: 0 (don’t interpolate)  
               example: fillgaps=3 (interpolate gaps 3 channels wide and narrower)  
       degamp -- Polynomial degree for BPOLY amplitude solution  
               default: 3; example: degamp=2  
       degphase -- Polynomial degree for BPOLY phase solution  
               default: 3; example: degphase=2  
       visnorm -- Normalize data prior to BPOLY solution  
               default: False; example: visnorm=True  
       maskcenter -- Number of channels to avoid in center of each band  
               default: 0; example: maskcenter=5 (BPOLY only)  
       maskedge -- Fraction of channels to avoid at each band edge (in %)  
               default: 5; example: maskedge=3 (BPOLY only)  
       append -- Append solutions to the (existing) table  
               default: False; example: append=True  
 
      --- Other calibrations to apply on the fly before determining bandpass solution  
 
      gaintable -- Gain calibration table(s) to apply  
               default: ’’ (none);  
               examples: gaintable=’ngc5921.gcal’  
                         gaintable=[’ngc5921.ampcal’,’ngc5921.phcal’]  
      gainfield -- Select a subset of calibrators from gaintable(s)  
               default:’’ ==> all sources in table;  
               same syntax as field  
               example: gainfield=’0~3’  
                        gainfield=[’0~3’,’4~6’]  
      interp -- Interpolation mode (in time) to use for each gaintable  
                default: ’’ --> ’linear’ for all gaintable(s)  
                example: interp=’nearest’  
                         interp=[’nearest’,’linear’]  
                Options: ’nearest’, ’linear’, ’aipslin’  
      spwmap -- Spectral windows combinations to form for gaintable(s)  
                default: [] (apply solutions from each spw to that spw only)  
                Example:  spwmap=[0,0,1,1] means apply the caltable solutions  
                          from spw = 0 to the spw 0,1 and spw 1 to spw 2,3.  
                          spwmap=[[0,0,1,1],[0,1,0,1]]  
      gaincurve -- Apply internal VLA antenna gain curve correction  (True/False)  
               default: False;  
               Use gaincurve=True ONLY for VLA data  
      opacity -- Opacity correction to apply (nepers)  
               default: 0.0 (no opacity correction)  
               example: opacity=0.051  
               Typical VLA values are: 5 GHz - 0.013, 8 GHz - 0.013  
               15 GHz - 0.016, 23 GHz - 0.051, 43 GHz - 0.07  
      parang -- If True, apply the parallactic angle correction (required  
               for polarization calibration)  
               default: False  
 

Please send any comments or questions about CASA or AIPS++ to aips2-requests@nrao.edu

Copyright © 2008 Associated Universities Inc., Washington, D.C.

This code is available under the terms of the GNU General Public Lincense


Home | Contact Us | Directories | Site Map | Help | Privacy Policy | Search

Updated daily during alpha development.