Synopsis
setcannedpb(telescope, othertelescope, dopb, commonpb, dosquint, paincrement, usesymmetricbeam)
Description
We have many vp/pb models ready to go for a variety of telescopes. If 'DEFAULT' is
selected, the system default for that telescope and frequency is used.
Arguments
telescope |
|
Which telescope in the MS will use this vp/pb? |
|
|
Allowed: |
String |
othertelescope |
|
If telescope=="OTHER", specify name here |
|
|
Allowed: |
String |
dopb |
|
Should we apply the vp/pb to this telescope's data? |
|
|
Allowed: |
Bool |
|
|
Default: |
T |
commonpb |
|
List of common vp/pb models: DEFAULT code figures it out |
|
|
Allowed: |
String |
|
|
Default: |
DEFAULT |
dosquint |
|
Enable the natural beam squint found in the common vp model |
|
|
Allowed: |
Bool |
|
|
Default: |
F |
paincrement |
|
Increment in Parallactic Angle for asymmetric (ie, squinted) vp application |
|
|
Allowed: |
Quantity |
|
|
Default: |
360deg |
usesymmetricbeam |
|
Not currently used |
|
|
Allowed: |
Bool |
|
|
Default: |
F |